Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Arq Bras Cardiol ; 94(5): e59-61, e122-4, 2010 May.
Artigo em Inglês, Português | MEDLINE | ID: mdl-20549027

RESUMO

The present case reports on a patient presenting the cardiac form of Chagas disease, with left ventricular dysfunction and second-degree atrioventricular block Mobitz type II, associated with several syncope episodes. The patient underwent a double-chamber definitive artificial pacemaker implant. One year after the implant, the displacement of the atrial electrode was diagnosed and the patient was submitted to re-implantation of the atrial electrode. Two years after the first surgical procedure, the patient presented dyspnea on exertion. The physical evaluation included an echocardiogram, which detected the presence of a foreign body with metallic characteristics in the left cardiac chambers, consistent with that of an ectopic pacemaker electrode.


Assuntos
Cardiomiopatia Chagásica/terapia , Eletrodos Implantados/efeitos adversos , Migração de Corpo Estranho/diagnóstico por imagem , Marca-Passo Artificial/efeitos adversos , Adulto , Bloqueio Atrioventricular/terapia , Cardiomiopatia Chagásica/diagnóstico por imagem , Humanos , Masculino , Reoperação/efeitos adversos , Ultrassonografia , Disfunção Ventricular Esquerda/etiologia
2.
Arq. bras. cardiol ; 94(5): e122-e124, maio 2010. ilus
Artigo em Inglês, Português | LILACS | ID: lil-548099

RESUMO

Apresentamos o caso de um paciente portador da forma cardíaca da doença de Chagas com disfunção ventricular esquerda e bloqueio atrioventricular de 2º grau Mobitz II, associados a vários episódios de síncope. Foi submetido a implante de marcapasso artificial definitivo dupla câmara. Após um ano do implante foi diagnosticado deslocamento de eletrodo atrial, sendo submetido a reimplante de eletrodo atrial. Após dois anos do primeiro procedimento cirúrgico, apresentava dispneia aos grandes esforços. Durante a avaliação, foi solicitado ecocardiograma, que detectou a presença de corpo estranho de características metálicas em câmaras cardíacas esquerdas, consistente com eletrodo de marcapasso ectópico.


The present case reports on a patient presenting the cardiac form of Chagas disease, with left ventricular dysfunction and second-degree atrioventricular block Mobitz type II, associated with several syncope episodes. The patient underwent a double-chamber definitive artificial pacemaker implant. One year after the implant, the displacement of the atrial electrode was diagnosed and the patient was submitted to re-implantation of the atrial electrode. Two years after the first surgical procedure, the patient presented dyspnea on exertion. The physical evaluation included an echocardiogram, which detected the presence of a foreign body with metallic characteristics in the left cardiac chambers, consistent with that of an ectopic pacemaker electrode.


Assuntos
Adulto , Humanos , Masculino , Cardiomiopatia Chagásica/terapia , Eletrodos Implantados/efeitos adversos , Migração de Corpo Estranho , Marca-Passo Artificial/efeitos adversos , Bloqueio Atrioventricular/terapia , Cardiomiopatia Chagásica , Reoperação/efeitos adversos , Disfunção Ventricular Esquerda/etiologia
3.
Arq Neuropsiquiatr ; 64(2A): 245-8, 2006 Jun.
Artigo em Português | MEDLINE | ID: mdl-16791364

RESUMO

The association between patent foramen ovale (PFO) and paradoxical emboli is described in medical literature. When have not association with atrial septal aneurysm, arguments arise about the clots origin, because it have been difficult to gave evidence of the clots passing from venous circulation across shunt right to left. We describe four cases of vascular events whose transesophageal echocardiography showed clots nailed within the PFO associated the prominent Eustachian valve, without septal aneurysm. This paper aim to illustrate and to warm about the potentially role of the PFO and Eustachian valve in the paradoxical embolism.


Assuntos
Embolia Paradoxal/etiologia , Comunicação Interatrial/complicações , Embolia Pulmonar/etiologia , Acidente Vascular Cerebral/etiologia , Adulto , Idoso , Ecocardiografia Transesofagiana , Evolução Fatal , Feminino , Comunicação Interatrial/diagnóstico , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
4.
Arq. neuropsiquiatr ; 64(2a): 245-248, jun. 2006. ilus
Artigo em Português | LILACS | ID: lil-429692

RESUMO

A associação entre forame oval patente (FOP) e embolia paradoxal é assunto já descrito na literatura médica. Quando não existe associação com aneurisma de septo atrial, surgem dúvidas quanto à origem do trombo devido à dificuldade que se tem de documentar a passagem de êmbolos vindos da circulação venosa pelo shunt direita-esquerda. Descrevemos quatro casos de eventos vasculares, cujos ecocardiogramas transesofágicos demonstraram a presença de trombo aderido ao FOP associado à válvula de Eustáquio proeminente na ausência de aneurisma de septo. Esse artigo visa ilustrar e chamar atenção para o potencial papel do FOP e da válvula de Eustáquio na ocorrência da embolia paradoxal.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Embolia Paradoxal/etiologia , Comunicação Interatrial/complicações , Embolia Pulmonar/etiologia , Acidente Vascular Cerebral/etiologia , Ecocardiografia Transesofagiana , Evolução Fatal , Comunicação Interatrial/diagnóstico , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...